The undercut anchor with an internal thread for M6 threaded screws for natural stone or artificial concrete panels.

Zykon panel anchors FZP II M6i PA

The undercut anchor with internal thread for a concealed flush or stand-off installation of heavy façade panels out of natural stone. Calibrated panels or reveal panels can be flush mounted and panel tolerances can be adjusted through the stand-off installation. Due to the internal thread, there is no protruding external thread. Thus panels can be prefabricated and transported in a space-saving manner. This improves the economic efficiency and flexibility of the system.
Produkt varijanteDownload of image data

Produkt varijante

1 produkt varijanti
Min. panel thickness
Total length
Thread
Cylindrical diameter
Undercutdiameter
Amount
Pregledano 1 od 1 verzija

Prednosti / opis proizvoda

Advantages
  • The integrated internal thread allows panels to be pre-fabricated and transported securely.
  • The matching shape of the undercut anchor creates a inter-locking and stress-free fixing in the conical undercuted drill hole.
  • The fixing is not externally visible, creating a visually appealing façade surface.
  • Setting the anchor using undercut technology allows the user to select the best structural position in the façade panel. This significantly reduces the bending moment of the panel.
  • The anchor allows higher failure loads compared to common systems.

Upotreba i atesti

Applications
  • Indoor applications (such as wash basins, natural stone heating systems, ...)
  • Exterior façades
  • Interior façades
  • Façade reveals
Building materials
  • Natural stone (>20mm)
Primjenjuju se pojedinosti (građevinski materijali, opterećenja itd.) bilo kojeg dostupnog odobrenja. Dodatne dokumente možete pronaći u Download Center.

Uputstva za montažu

Functionality
  • The hole is either drilled to a constant reference dimension for the remaining wall thickness (RWT) or with an absolute anchoring depth.
  • The anchor can be installed flush or stand-off.
  • The compensation of panel thickness tolerances results in a completely flat façade surface.
  • Wet diamond drilling: first cylindrical, then conical - to create the undercut. #Inserting the undercut anchor in the cylindrical-conical undercut hole
  • Expanding the undercut anchor by "pressing down" the washer using the setting tools
  • Stress-free and geometrical inter-locking fixing
Mounting Strip 1 Picture
1 / 4